RainBlade 2900 TrueLine

  • Flush-front low profile aesthetically pleasing framing design
  • High-performance rain screen design featuring NEW interior rainblade gasket
  • Eliminates the need for foam backer rods and precise caulking applications
  • For punched opening applications
  • High-performance polyamide strut thermal break
  • Dual Finish interior/exterior possible
  • Seamlessly integrate with Alumicor vents
  • Interior-glazed system
  • 2-1/4” (57.2mm) Sight Line
  • Frame depths of 4-1/4” (108 mm), 5” (127mm) for 1” (25.4mm) dual-glazed system
  • Frame depths of 5” (127 mm), 5-3/4” (146mm) for 1-3/4” (44.5mm) triple-glazed system
  • Trouble-free notched and 45° mitred fabrication options
  • Interior prime-seal gasket eliminates the need for sealant heel beads
  • Designed to readily accept Tremco Proglaze Engineered Transition Assembly (ETA)

RainBlade 2900 TrueLine

  • Flush-front low profile aesthetically pleasing framing design
  • High-performance rain screen design featuring NEW interior rainblade gasket
  • Eliminates the need for foam backer rods and precise caulking applications
  • For punched opening applications
  • High-performance polyamide strut thermal break
  • Dual Finish interior/exterior possible
  • Seamlessly integrate with Alumicor vents
  • Interior-glazed system
  • 2-1/4” (57.2mm) Sight Line
  • Frame depths of 4-1/4” (108 mm), 5” (127mm) for 1” (25.4mm) dual-glazed system
  • Frame depths of 5” (127 mm), 5-3/4” (146mm) for 1-3/4” (44.5mm) triple-glazed system
  • Trouble-free notched and 45° mitred fabrication options
  • Interior prime-seal gasket eliminates the need for sealant heel beads
  • Designed to readily accept Tremco Proglaze Engineered Transition Assembly (ETA)
RainBlade 2900 TrueLine Product Specifications
Application: For punched opening applications.
Description: Flush-front high-performance rain screen design, interior-glazed fixed window.
Glazing Frame Depths Air Infiltration/Exfiltration Water Structural U-Factor
(NFRC 102)
CRF (AAMA 1503) CONDENSATION INDEX
(CSA A440.2)
ACOUSTIC (ASTM-E90) AAMA/WDMA/CSA 101/I.S.2/A440-17 and CSA A440S1-17 Forced Entry (ASTM F588)
Dual Glazed 4-1/4″ (108mm)*
5″ (127mm)
Receptor: No
Infiltration:
< 0.1 cfm/ft2 @ 6.27 psf
Exfiltration:
< [0.5 L/s•m2 @ 300 Pa] Level A3
720Pa
(15psf)
Design:
+/- 3.84kPa (+/- 80 psf)
Overload:
+/- 5.76kPa (+/- 120 psf)
U-Factor Table 76 70 STC 31, OITC 25 AW-PG80 Grade 40
Triple Glazed 5” (127mm)*
5 3/4” (146mm)
Receptor: No
Infiltration:
< 0.1 cfm/ft2 @ 6.27 psf
Exfiltration:
< [0.5 L/s•m2 @ 300 Pa] Level A3
720Pa
(15psf)
Design:
+/- 3.84kPa (+/- 80 psf)
Overload:
+/- 5.76kPa (+/- 120 psf)
U-Factor Table 84 77 STC 34, OITC 26 AW-PG80 Grade 40

* Note: System Frame depths used for thermal testing and reflected in performance values under U-factor and CRF

RainBlade 2900 TrueLine Product Specification
Application: For punched opening applications.
Description: Flush-front high-performance rain screen design, interior-glazed fixed window.
Frame Depth Dual Glazed:
4 ¼” (108mm)*
5” (127mm)
Receptor: No
Triple Glazed:
5” (127mm)*
5 3/4” (146mm)
Receptor: No
Infiltration/ Exfiltration Dual Glazed:
Infiltration:
< 0.1 cfm/ft2 @ 6.27 psf
Exfiltration:
< [0.5 L/s•m2 @ 300 Pa] Level A3
Triple Glazed:
Infiltration:
< 0.1 cfm/ft2 @ 6.27 psf
Exfiltration:
< [0.5 L/s•m2 @ 300 Pa] Level A3
Water Dual Glazed:
720Pa
(15psf)
Triple Glazed:
720Pa
(15psf)
Structural Dual Glazed:
Design:
+/- 3.84kPa (+/- 80 psf)
Overload:
+/- 5.76kPa (+/- 120 psf)
Triple Glazed:
Design:
+/- 3.84kPa (+/- 80 psf)
Overload:
+/- 5.76kPa (+/- 120 psf)
U-Factor (NFRC 102) U-Factor Table U-Factor Table
CRF (AAMA 1503) Dual Glazed:
76
Triple Glazed:
84
CONDENSATION INDEX
(CSA A440.2)
Dual Glazed:
70
Triple Glazed:
77
ACOUSTIC (ASTM-E90) Dual Glazed:
STC 31, OITC 25
Triple Glazed:
STC 34, OITC 26
AAMA/WDMA/CSA 101/I.S.2/A440-17 and CSA A440S1-17 AW-PG80  AW-PG80
ACOUSTIC (ASTM-E90) Grade 40 Grade 40

* Note: System Frame depths used for thermal testing and reflected in performance values under U-factor and CRF

Specifications
WindLoad and DeadLoad Charts
Product Details – DWG Dual-Glazed

Triple-Glazed

Catalogue Pages
Installation Instructions/Parts List
Air-Water-Structural
Thermal
1in. IGU
1.75in. IGU
Acoustic

EXAMPLES >

Shell Canada
Fort Saint John, BC