RainBlade 2990 FeatureLine
- Capped full rain screen design, simulates a curtainwall’s appearance
- High-performance rain screen design featuring NEW interior rainblade gasket
- For ribbon or punched opening applications
- High-performance polyamide strut thermal break
- Possibility of two-color finishes (interior/exterior)
- Seamlessly integrate with Alumicor vents
- Interior-glazed system
- 2 1/4 (57.2mm) Sight Line
- Frame depths of 5-1/4 (134 mm), 6” (153mm) for 1” (25.4mm) double-glazed system
- Frame depths of 6 (153 mm), 6-3/4” (171mm) for 1-3/4” (44.5mm) triple-glazed system
- Head/sill receptor options
- Trouble-free notched and 45° mitred fabrication options
- Can be shop-glazed (optional header and split mullions details)
- Interior prime-seal gasket eliminates the need for sealant heel beads
- Designed to readily accept Tremco Proglaze Engineered Transition Assembly (ETA)
RainBlade 2990 FeatureLine
- Capped full rain screen design, simulates a curtainwall’s appearance
- High-performance rain screen design featuring NEW interior rainblade gasket
- For ribbon or punched opening applications
- High-performance polyamide strut thermal break
- Possibility of two-color finishes (interior/exterior)
- Seamlessly integrate with Alumicor vents
- Interior-glazed system
- 2 1/4 (57.2mm) Sight Line
- Frame depths of 5-1/4 (134 mm), 6” (153mm) for 1” (25.4mm) double-glazed system
- Frame depths of 6 (153 mm), 6-3/4” (171mm) for 1-3/4” (44.5mm) triple-glazed system
- Head/sill receptor options
- Trouble-free notched and 45° mitred fabrication options
- Can be shop-glazed (optional header and split mullions details)
- Interior prime-seal gasket eliminates the need for sealant heel beads
- Designed to readily accept Tremco Proglaze Engineered Transition Assembly (ETA)
RainBlade 2990 FeatureLine Product Specifications | ||||||||||
Application: For ribbon or punched opening applications. Description: Capped full rain screen design, interior-glazed window. |
||||||||||
Glazing | Frame Depths | Air Infiltration/Exfiltration | Water | Structural | U-Factor (NFRC 102) |
CRF (AAMA 1503) | CONDENSATION INDEX (CSA A440.2) |
ACOUSTIC (ASTM-E90) | AAMA/WDMA/CSA 101/I.S.2/A440-17 and CSA A440S1-17 | Forced Entry (ASTM-F588) |
Dual Glazed | 5 ¼” (134mm)* 6” (153mm) Receptor: Yes |
Infiltration: < 0.1 cfm/ft2 @ 6.27 psf Exfiltration: < [0.5 L/s•m2 @ 300 Pa] Level A3 |
720Pa (15psf) |
Design: +/- 3.84kPa (+/- 80 psf) Overload: +/- 5.76kPa (+/- 120 psf) |
U-Factor Table | 75 | 68 | STC 30, OITC 25 | AW-PG80 | Grade 40 |
Triple Glazed | 6” (153mm)* 6 ¾” (171mm) Receptor: Yes |
Infiltration: < 0.1 cfm/ft2 @ 6.27 psf Exfiltration: < [0.5 L/s•m2 @ 300 Pa] Level A3 |
720Pa (15psf) |
Design: +/- 3.84kPa (+/- 80 psf) Overload: +/- 5.76kPa (+/- 120 psf) |
U-Factor Table | 84 | 77 | STC 33, OITC 26 | AW-PG80 | Grade 40 |
* Note: System Frame depths used for thermal testing and reflected in performance values under U-factor and CRF
RainBlade 2990 FeatureLine Product Specification | ||
Application: For ribbon or punched opening applications. | ||
Description: Capped full rain screen design, interior-glazed window. | ||
Frame Depth | Dual Glazed: 5 ¼” (134mm)* 6” (153mm) Receptor: Yes |
Triple Glazed: 6” (153mm)* 6 ¾” (171mm) Receptor: Yes |
Infiltration/ Exfiltration | Dual Glazed: Infiltration: < 0.1 cfm/ft2 @ 6.27 psf Exfiltration: < [0.5 L/s•m2 @ 300 Pa] Level A3 |
Triple Glazed: Infiltration: < 0.1 cfm/ft2 @ 6.27 psf Exfiltration: < [0.5 L/s•m2 @ 300 Pa] Level A3 |
Water | Dual Glazed: 720Pa (15psf) |
Triple Glazed: 720Pa (15psf) |
Structural | Dual Glazed: Design: +/- 3.84kPa (+/- 80 psf) Overload: +/- 5.76kPa (+/- 120 psf) |
Triple Glazed: Design: +/- 3.84kPa (+/- 80 psf) Overload: +/- 5.76kPa (+/- 120 psf) |
U-Factor (NFRC 102) | U-Factor Table | U-Factor Table |
CRF (AAMA 1503) | Dual Glazed: 75 |
Triple Glazed: 84 |
CONDENSATION INDEX (CSA A440.2) |
Dual Glazed: 68 |
Triple Glazed: 77 |
ACOUSTIC (ASTM-E90) | Dual Glazed: STC 30, OITC 25 |
Triple Glazed: STC 33, OITC 26 |
AAMA/WDMA/CSA 101/I.S.2/A440-17 and CSA A440S1-17 | AW-PG80 | AW-PG80 |
Forced Entry (ASTM F588) | Grade 40 | Grade 40 |
* Note: System Frame depths used for thermal testing and reflected in performance values under U-factor and CRF