UniVent 1375AW Insert Vent

  • Adjustable hardware.
  • Handle finishes in Silver, White and Black.
  • Can be integrated in all Alumicor curtain wall, storefront and fixed window systems
  • Open-in (Hopper & Casement) and Open-out (Awning & Casement) vent options
  • Polyamide thermal break permits two-color interior/exterior finishes
  • U-factor of 2,10 W/m²•K in Dual Glazing and of 1,48 W/m²•K in Triple Glazing
  • 2 3/4” (69.85mm) System Depth – Dual IGU
  • 3 7/16″ (87.3mm) System Depth – Triple IGU
  • Open-out Casement/Awning Vent have CAM handles.
  • Open-out Casement/Awning Vents with optional Custodial Lock have Roto-operator/Multi-point locking hardware.
  • Open-out Awning Vent with optional ADA Handle have Roto-operator/Multi-point locking hardware.
  • Open-in Hopper/Casement Vent with optional Custodial Lock have a central seal and multi-point locking hardware.
  • Factory-fabricated at Alumicor facilities
  • 2-year std warranty (can be extended to 5-year)

Let fresh air into the building using natural ventilation with Alumicor’s new UniVent 1375AW Series . These operable vents are engineered to complement and seamlessly integrate within mid- to high-rise commercial buildings’ storefront, fixed windows and curtainwall systems

These AW rated vents have a frame depth of 2-3/4″ (70mm) for dual glazed and 3-1/2″ (89mm) for triple glazed IGU’s with mitered/sealed corners and crimped on an “L” shaped clip. Dimensions span up to 72 by 36 inches (1828.8mm x 914.4mm) for hoppers, and up to 36 by 62 (914.4mm x 1574.8mm) inches for casements.

UniVent 1375AW Series are tested to meet AW Performance Class, the most stringent performance and durability requirements of North American Fenestration Standard /Specification for windows, doors, and skylights (NAFS-17) plus the AAMA/WDMA/CSA 101/I.S.2/A440-19 Canadian supplement. This industry standard includes high-performance criteria for air, water and structural integrity, lifecycle testing to 4,000 operating cycles.

These aluminum-framed vents are thermally broken and insulated with polyamide strut, providing a U-factor of 2,10 W/m²•K with dual-glazed IGUs and 1,48 W/m²•K with triple-glazed, per NFRC 102-2020. A frame condensation resistance factor (CRFf) of 72 per AAMA 1503-09 and a Global Temperature Index of 67 per CSA A440.2/A440.3 also can be achieved in combination with triple-pane IGUs further contributing to high-performance, energy-efficient building envelopes.

Screens may be ordered and finished to match the vent frame. The aluminum framing is available in high-performance standard anodized or paint finishes. Specialty finishes, custom colors and dual finishes also may be specified.

Casement Vent

Awning Vent

Hopper Vent

UniVent 1375AW Insert Vent

  • Adjustable hardware.
  • Handle finishes in Silver, White and Black.
  • Can be integrated in all Alumicor curtain wall, storefront and fixed window systems
  • Open-in (Hopper & Casement) and Open-out (Awning & Casement) vent options
  • Polyamide thermal break permits two-color interior/exterior finishes
  • U-factor of 2,10 W/m²•K in Dual Glazing and of 1,48 W/m²•K in Triple Glazing
  • 2 3/4” (69.85mm) System Depth – Dual IGU
  • 3 7/16″ (87.3mm) System Depth – Triple IGU
  • Open-out Casement/Awning Vent have CAM handles.
  • Open-out Casement/Awning Vents with optional Custodial Lock have Roto-operator/Multi-point locking hardware.
  • Open-out Awning Vent with optional ADA Handle have Roto-operator/Multi-point locking hardware.
  • Open-in Hopper/Casement Vent with optional Custodial Lock have a central seal and multi-point locking hardware.
  • Factory-fabricated at Alumicor facilities
  • 2-year std warranty (can be extended to 5-year)

Let fresh air into the building using natural ventilation with Alumicor’s new UniVent 1375AW Series . These operable vents are engineered to complement and seamlessly integrate within mid- to high-rise commercial buildings’ storefront, fixed windows and curtainwall systems

These AW rated vents have a frame depth of 2-3/4″ (70mm) for dual glazed and 3-1/2″ (89mm) for triple glazed IGU’s with mitered/sealed corners and crimped on an “L” shaped clip. Dimensions span up to 72 by 36 inches (1828.8mm x 914.4mm) for hoppers, and up to 36 by 62 (914.4mm x 1574.8mm) inches for casements.

UniVent 1375AW Series are tested to meet AW Performance Class, the most stringent performance and durability requirements of North American Fenestration Standard /Specification for windows, doors, and skylights (NAFS-17) plus the AAMA/WDMA/CSA 101/I.S.2/A440-19 Canadian supplement. This industry standard includes high-performance criteria for air, water and structural integrity, lifecycle testing to 4,000 operating cycles.

These aluminum-framed vents are thermally broken and insulated with polyamide strut, providing a U-factor of 2,10 W/m²•K with dual-glazed IGUs and 1,48 W/m²•K with triple-glazed, per NFRC 102-2020. A frame condensation resistance factor (CRFf) of 72 per AAMA 1503-09 and a Global Temperature Index of 67 per CSA A440.2/A440.3 also can be achieved in combination with triple-pane IGUs further contributing to high-performance, energy-efficient building envelopes.

Screens may be ordered and finished to match the vent frame. The aluminum framing is available in high-performance standard anodized or paint finishes. Specialty finishes, custom colors and dual finishes also may be specified.

Casement Vent

Awning Vent

Hopper Vent

Univent 1375AW Insert Vent Awning Casement Hopper Casement
Application Project Out Project Out Project In Project In
Frame Joints Mitered, 2 Corner Keys
Window Joints Mitered, 2 Corner Keys
Glass Thickness 1” (25.4mm), 1 1/16” (27mm), 1 ¾ (44.5mm)
Face Width 3-1/16″ (78mm) Dual
3-7/16” (87mm) Triple
3-1/16″ (78mm) Dual
3-7/16” (87mm) Triple
2-7/16″ (62mm) Dual
3-7/16” (87mm) Triple
3-3/16″ (80mm) Dual
3-7/16” (87mm) Triple
Frame Depth 3-15/32″ (88mm) 3-15/32″ (88mm) 3-7/16″ (87.8mm) 3-7/16″ (87.8mm)
Hardware 4-bar hinges, Cam Lock or optional roto operator with Multi-point lock or optional custodial lock with removable handle Butt hinges, Cam lock, optional roto operator with Multi-point lock handle or optional custodial lock with removable handle, optional egress lock with opening restrictor 4-Bar hinges, Multi point lock handle, optional custodial lock with removable handle 4-Bar hinge or concealed Euro Hinge with Multi point lock handle, optional custodial lock with removable handle. Optional Egress with opening restrictor
ASTM E331 AND E547
Uniform and Cyclic
Static Water
15 PSF (720Pa)
U-Factor** Dual: 2,10 W/m² • K
Triple: 1,48W/m² • K
Dual: 2,10 W/m² • K
Triple: 1,41W/m² • K
Air Infiltration and
Exfiltration @300Pa
0,3 L/s•m²
A3
0,3 L/s•m²
A3
0,5 L/s•m²
A3
0,3 L/s•m²
A3
AAMA/WDMA/CSA 101
I.5.2/A440-17, NAFS
AW-PG80* AW PG80* AW PG80 AW PG80
AAMA910 Life Cycle 4000 Cycles
CRF (AAMA 1503-2010)
Condensation Resistance Factor
Dual: 69 / Triple: 72 Dual: 62 / Triple: 70
Temperature Index
(CSA A440.2/A440.3)
Dual: 57 / Triple: 67 Dual: 49 / Triple: 56
Acoustic 1” (25mm) : 35 STC / 29 OITC; 1 1/16” (27mm) : 39 STC / 34 OITC; 1 3/4” (44mm) : 36 STC / 29 OITC 1” (25mm) : 36 STC / 30 OITC, 1 1/16” (27mm) : 39 STC / 33 OITC; 1 3/4” (44mm) : 36 STC / 29 OITC
Forced Entry (ASTM F588) Grade 40

*AW PG60 (with Cam Lock) **U-Factor per NFRC 100

Univent 1375AW Insert Vent Awning
Application Project Out
Frame Joints Mitered, 2 Corner Keys
Window Joints Mitered, 2 Corner Keys
Glass Thickness 1” (25.4mm), 1 1/16” (27mm), 1 ¾ (44.5mm)
Face Width 2-3/4″ (70mm) Dual
3-7/16” (87mm) Triple
Frame Depth

2-3/4″ (70mm) Dual

Hardware 4-bar hinges, Cam Lock or optional roto operator with Multi-point lock or optional custodial lock with removable handle
ASTM E331 AND E547 Uniform
and Cyclic Static Water
15 PSF (720Pa)
U-Factor**

Dual: 2, 10W/m² • K
Triple: 1, 48W/m² • K

Air Infiltration and
Exfiltration @300pa
0,3 L/s•m²
A3
AAMA/WDMA/CSA 101
I.5.2/A440-17, NAFS Testing
AW-PG80*
AAMA910 Life Cycle

4000 Cycles

CRF (AAMA 1503-2010)
Condensation Resistance Factor

Dual: 69 / Triple: 72

Temperature Index
(CSA A440.2/A440.3)

Dual: 57 / Triple: 67

Acoustic:

1” 35 STC/29 OITC, 1 1/16” 39 STC/34 OITC, 1 3/4” 36 STC/29 OITC

ASTM F588

Grade 40
Forced Entry

Guide Specification Coming Soon
Perimeter Sheet – DWG / PDF
Dual Glazed |
Triple Glazed |
Catalogue Pages
Installation Instructions
Air-Water-Structural
Dual Glazed
Dual Glazed Cam Locks
Triple Glazed
Thermal
Dual Glazed
Triple Glazed
Acoustic
Guide Specification Coming Soon
Perimeter Sheet – DWG / PDF
Dual Glazed |
Triple Glazed |
Catalogue Pages
Installation Instructions
Air-Water-Structural
Dual Glazed
Triple Glazed
Thermal
Dual Glazed
Triple Glazed
Acoustic
Guide Specification Coming Soon
Perimeter Sheet – DWG / PDF
Dual Glazed Project Out |
Triple Glazed Project Out |
Dual Glazed Project In |
Triple Glazed Project In |
Catalogue Pages
Installation Instructions
Air-Water-Structural
Dual Glazed PO
Triple Glazed PO
Dual Glazed PI
Triple Glazed PI
Thermal
Dual Glazed
Triple Glazed
Acoustic