ThermaWall TW2200

  • 2 inch (50.8 mm) Sight Line
  • Mullion depths from 50.8 mm (2”) to 127 mm (5”)
  • Conventional captured and structural silicone glazed (SSG) options
  • High performing polyamide thermal break provides improved U-factor and resistance to condensation
  • Dual or Triple glazed options
  • Compatible with all Alumicor operable windows, doors, etc.
  • A variety of pressure plate caps are available
  • Custom offset pressure plate
  • Alumicor glass support eliminates concerns of dead loads imposed upon thermal breaks
  • Proprietary gasket provides improved thermal performance

ThermaWall TW2200

  • 2 inch (50.8 mm) Sight Line
  • Mullion depths from 50.8 mm (2”) to 127 mm (5”)
  • Conventional captured and structural silicone glazed (SSG) options
  • High performing polyamide thermal break provides improved U-factor and resistance to condensation
  • Dual or Triple glazed options
  • Compatible with all Alumicor operable windows, doors, etc.
  • A variety of pressure plate caps are available
  • Custom offset pressure plate
  • Alumicor glass support eliminates concerns of dead loads imposed upon thermal breaks
  • Proprietary gasket provides improved thermal performance
ThermaWall TW2200 Product Specifications
Application: Low to mid rise commercial buildings requiring high performance including retail, education, health care, office.
Description: Thermally broken, field-glazed, shear block curtainwall.
Face
Width:
System
Depth:
Back Member
Depth:
Glass: Air: Water: Structural: U-Factor:
Sight Line
50.8mm (2″)
Dual Glazed:
108.0mm – 184.2mm (4 1/4″ – 7 1/4″)
Triple Glazed:
127.0mm – 203.2mm (5″ – 8″)
50mm (2”), 69.9mm(2 3/4”),
101.6mm (4”), 127mm (5”)
Dual Glazed:
25.4mm (1″)
Triple Glazed:
44.5mm (1 3/4″)
0.00005 m3 /s/m2
(0.01069 cfm/ft2) @300Pa (6psf)
720Pa
(15psf)
Uniform:
1676 Pa(35 psf)
Structural:
2514 Pa (52.5 psf )
U-Factor Table
ThermaWall TW2200 Product Specification
Application: Low to mid rise commercial buildings requiring high performance including retail, education, health care, office.
Description: Thermally broken, field-glazed, shear block curtainwall.
Face Width: Sight Line 50.8mm (2″)
System Depth: Dual Glazed: 108.0mm – 184.2mm (4 1/4″ – 7 1/4″)
Triple Glazed: 127.0mm – 203.2mm (5″ – 8″)
Back Member Depth: 50mm (2”), 69.9mm (2 3/4”), 101.6mm (4”), 127mm (5”),
Glass: Dual Glazed: 25.4mm (1″)
Triple Glazed: 44.5mm (1 3/4″)
Air: 0.00005 m3 /s/m2 (0.01069 cfm/ft2) @300Pa (6psf)
Water: 720Pa (15psf)
Structural: Uniform: 1676 Pa (35 psf)
Structural: 2514 Pa (52.5 psf )
U-Factor: U-Factor Table
Specifications
WindLoad & DeadLoad Charts
Product Details – DWG
Dual Glazed Triple Glazed
50.8 mm (2″) Frame
69.85 mm (2.75″) Frame
101.6 mm (4″) Frame
127 mm (5″) Frame
Catalogue Pages
Parts List