TrueLine 900

  • Fixed prime-sealed interior-glazed window for ribbon or punched window applications
  • Flush-front profile with frame depths from 2-1/2″ (63.5mm) up to 5″ (127.0mm)
  • All Alumicor projected windows and specialty windows systems can be integrated
  • 2 1/4″ (57.2mm) Sight Line
  • Foamed PVC barrier for improved thermal performance
  • Can accommodate any glass or IGU depth
  • Optional top-load gasket eliminates loose gasket problems caused by undersized insulating glass units (IGUs)
  • Trouble-free lap joint or notched fabrication
  • Dual-finish option (interior/exterior finishes)

TrueLine 900

  • Fixed prime-sealed interior-glazed window for ribbon or punched window applications
  • Flush-front profile with frame depths from 2-1/2″ (63.5mm) up to 5″ (127.0mm)
  • All Alumicor projected windows and specialty windows systems can be integrated
  • 2 1/4″ (57.2mm) Sight Line
  • Foamed PVC barrier for improved thermal performance
  • Can accommodate any glass or IGU depth
  • Optional top-load gasket eliminates loose gasket problems caused by undersized insulating glass units (IGUs)
  • Trouble-free lap joint or notched fabrication
  • Dual-finish option (interior/exterior finishes)
Trueline 900 Product Specifications
Application: For ribbon or punched opening applications.
Description: Interior-glazed prime-sealed or rain screen design with flush-front profile.
Face
Width:
System
Depth:
Glass: Air: Water: Structural: U-Factor:
Sight Line:
57.2mm (2 1/4″)
Dual Glazed:
128.6mm (5 1/16″)
Triple Glazed:
127.0mm (5″)
Dual Glazed:
25.4mm (1″)
Triple Glazed:
44.5mm (1 3/4″)
0.006 L/s.m.2 (0.127
cfm/ft2) @300Pa (6psf)
730Pa (15psf) Design:
3360Pa (70psf )
Overload:
5040Pa (105 psf)
U-Factor Table
Trueline 900 Product Specification
Application: For ribbon or punched opening applications.
Description: Interior-glazed prime-sealed or rain screen design with flush-front profile.
Face Width: Sight Line: 57.2mm (2 1/4″)
System Depth: Dual Glazed: 128.6mm (5 1/16″)
Triple Glazed: 127.0mm (5″)
Glass: Dual Glazed: 25.4mm (1″)
Triple Glazed: 44.5mm (1 3/4″)
Air: 0.006 L/s.m.2 (0.127 cfm/ft2) @300Pa (6psf)
Water: 730Pa (15psf)
Structural: Design: 3360Pa (70psf )
Overload: 5040Pa (105 psf)